Ease Medical Apparatus And Instruments
| Product name | Model | Specification | Material | Code |
|---|---|---|---|---|
| Fibular Nail Mini nail | SWX-IIIS | 3.0×145 | Titanium Alloy | 15883145 |
| Product name | Model | Specification | Material | Code |
|---|---|---|---|---|
| Proximal Femoral Nail Antirotation | SGM-IIK | 9.0×170×130° | Titanium Alloy | 15649170 |
| Proximal Femoral Nail Antirotation | SGM-IIK | 9.0×200×130° | Titanium Alloy | 15649200 |
| Proximal Femoral Nail Antirotation | SGM-IIK | 9.0×240×130° | Titanium Alloy | 15649240 |
| PFNA End Cap | SGM-IIK | 10×15 | Titanium Alloy | 15601115 |
| PFNA End Cap | SGM-IIK | 10×20 | Titanium Alloy | 15601120 |
| PFNA Blade | SGM-IIK | 10.5×70 | Titanium Alloy | 15600570 |
| PFNA Blade | SGM-IIK | 10.5×80 | Titanium Alloy | 15600580 |
| Locking screw | SGM-IIK | 4.9×30--72 | Titanium Alloy | 15604930 |
| Femoral Nail locking screw I | SGG-IIIK | 6.5×75 | Titanium Alloy | 15246575 |
| Femoral Intramedullary Nail | SGG-IIIK | 9.0-13.0 | Titanium Alloy | 15249340 |
| Humeral Intramedullary Nail | SHG-IK | 8 | Titanium Alloy | 15728160 |


The length is consistent with the anatomy of the FEMORAL medullary cavity.

To further improve the fixation strength of osteoporosis. The Blunt End Design of the locking screw reduces the risk of excessive penetration.

Short nail: diameter 8.0/9.5mm, length 160mm. Long nail: diameter 7.0/8.5mm, length 180-315mm. All nails have left and right types, made of titanium alloy. Suitable for all applications with minimally invasive implantation.

Multi-plane and Multi-locking screw fixation options for optimal stability. Screw-in-screw design improves fixation in osteoporosis. Blunt head and countersinking design reduces soft tissue irritation.
Short screw: two plane holes for locking. Long screw: three locking holes avoid important blood vessels. Anterior and posterior locking holes facilitate manual operation, minimizing rotation and displacement.


Nail diameter should be 30-40% of the narrowest transverse diameter of medullary cavity. Applications: 3mm for 6-8 years; 3.5mm for 9-11 years; 4.0mm for 12-14 years.
Special design of compression holes increases stability of transverse or short oblique fractures. Self-sustaining compression mechanism requires no static screw during operation.





We focus on the development, manufacturing, and sales of orthopedic trauma, spine, and bone joint implants. With first-class production equipment, professional R&D teams, and a quality management system in line with international standards, we provide high-quality orthopedic medical devices globally.


